Shop
Power⁺ VO | Outdoor VCB 3.3kV to 11kV
The Power⁺ VO are Outdoor VCB Switchgear Panels of voltage range 3.3kV to 11kV and current ratings from 630A to 3150A.
Outdoor Panels are of Kiosk Type construction with double doors in the front. The Rear door that is both hinged and bolted for safety. Robust weather and dust proof IP55 degree of protection externally and IP2X between compartments.
We believe in shorter lead times and faster response for our product customisations.
Specification Our Design Standards Outdoor Kiosk Panels
Panel : VCB Outdoor Kiosk Panel Breaker : IEC 62271:100 * Kiosk Type construction With Double door in the front shall be provided.
Breaker : Vmax (31.5KA and below) and VD4 for 40KA Current transformer : IS 2705/ * Rear door is both hinged and bolted for safety.
Supply voltage : 3.3kV, 6.6kV and 11kV 1992 and IEC 60044:1. * Adequate slope given on top roof to drain rain water, dust & Particles.
Rated current : 630A, 800A, 1250A, 2000A, 2500A, 3150A Potential transformer : IS 3156/ * Robust weather & dust proof – IP5X degree of protection
Short time current rating : 18.4, 25, 26.3, 31.5, 40kA 1992 and IEC 60044:2 externally & IP2X between compartments.
Degree of protection of panel : IP 4X, IP5X Busbar : IS 5082 for Aluminium
Sheet Enclosure : i) Prime grade sheet steel treated with 7 tank Sheet Steel : IS 513
process and duly powder coated for longevity OR ii) Supergalum Pre- Cables : IS 694 Salient Features –
coated Alu-zinc enclosure * Modular & compact for better strength and flexibility in extension.
Busbar : Electrical grade Aluminium or 99.9% Oxygen Free Copper * Fully Compartmentalized construction for optimal safety and protection
Relays : Numerical, Electromechanical relays for Feeder, Transformer, *For compactness in panels rated upto 2000A special bus raiser panel
Bus, Motor and Generator protections can be provided. is provided with bus coupler panel extended in the rear side.
Metering compartment : Is designed such that meters, indicating * IP4X degree of protection is provided externally & IP2X between compartments.
equipments, Relays are arranged to make maintenance and operation easy. * Our design enables adequate space for large cable sizes. Even larger cables and
Current / Potential transformer : i) Resin cast transformers designed for additional runs rear extension is provided for cost effectiveness.
low smoke and flame:retardant. ii) Ratios, Accuracy & burdens as per requirement. * Independent exhaust vents for all HT compartment are provided for
Standard dimensions of panel (Estimated) : W: 700 mm D: 1500 mm natural cooling and exit for any flue gasses.
for Incoming / Outgoing panel and 1950mm for IN/OUT type of panel. H: 2400 mm * Dedicated Circuit breaker compartment as per internationally proven ABB design.
*Cassette mounted ABB Circuit Breaker with draw out feature for easy maintenance and fail-safe safety.
- * Live parts covered by automatic metallic shutters when breaker is racked out.
- * Electrical anti-pumping design avoids mishaps due to mishandling of the breaker.
- *Additional feature includes a separate Racking in/out mechanism which is provided in the breaker which can change from “test” to “service”
- positions and vice versa with the cubicle door closed.
- * Only Branded and type tested sub components are used in our panels.
- * Current and Voltage transformers are placed in chamber below Circuit breaker to avoid any kind of flashovers which may damage the breaker.
- * Wiring done with flexible copper cable affirming to IS 694 for Longitivity and Durability.
- * Optional integral earth switch can be provided on the cable side for Earthing.
* We provide Foundation frame as standard supply
* All hinged doors are provided with gaskets to keep away dust and water from the electrical components.
* Breaker trolley shall be given along with the breaker panel for maintenance.