DIN-Rail Power Supplies (SMPS)
24 V DC and other DIN-rail switch-mode power supplies for control panels and automation.
On request- StandardIEC 61204-3, IEC 62368-1

Download specification sheet (PDF)
Field transmitters that convert process variables to 4-20 mA or digital signals.
Every field is optional - tell us what you know and we will confirm the rest in the quotation.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: pressure transmitter, temperature transmitter, level transmitter, 4-20 mA transmitter, process transmitter, industrial transmitters
Choose range so that normal operation lands in the middle of the span, not near either end, and leave headroom for upsets. For pressure, decide between gauge, absolute and differential types. For level, decide between hydrostatic (submersible or flange mounted), ultrasonic, radar or other technology based on the tank, medium and foaming or vapour.
Common errors include mounting a pressure transmitter where the process line pulsates without a snubber, and forgetting to ground cable screens at one end. Calibrate against a known reference before commissioning. Pair with a PLC analogue input and a stable 24 V supply.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
A current loop is less sensitive to cable resistance and noise than a voltage signal, and the 4 mA live zero lets the system detect a broken wire. A 2-wire transmitter takes both power and signal from the same pair, which simplifies wiring.
RTDs such as Pt100 are accurate and stable over a moderate range, and are common in utility and process work. Thermocouples cover much higher temperatures and respond faster but are less accurate. Choose by temperature range, accuracy and sensor placement.
A transmitter measures a process variable such as pressure, temperature or level and converts it to a standard signal, commonly 4 to 20 mA or a digital signal. This is sent to a PLC, controller or indicator for display and control.
It is a standard analogue current signal where 4 mA represents the lowest value of the measuring range and 20 mA the highest. The current signal is less affected by cable length and noise, and 4 mA also shows that the loop is live.
Choose the variable to be measured and its range, the output signal, the process connection, the material of parts in contact with the process, and a hazardous-area rating if the site needs it. The supply and protection degree should also be checked.
Send the variable and its range, output signal, process connection size and type, wetted material, process medium, any hazardous-area requirement and the quantity. SKE Bharat will prepare a quotation from these details.
| Product Type | Process transmitter |
|---|---|
| Standard | IEC 60770 (transmitters) |
| Selection Basis | Variable and range, output signal, process connection, wetted material, hazardous-area rating if needed |
| Typical Use | Process measurement |