Drive Panel Spares
Spares for drive and control panels: contactors, relays, fuses, power supplies, fans and control components.
On request- Spare TypePanel components
- Applies ToDrive and control panels
- Selection BasisMake, model and part number
Genuine spares for motors, drives, relays, substation and switchgear.
Spares for drive and control panels: contactors, relays, fuses, power supplies, fans and control components.
On requestSpares for electric motors: bearings, shafts, fans, terminal boxes, slip rings, brushes and windings.
On requestProtection, control and timing relays for motors, feeders, transformers and generators.
On requestSpares for substation equipment: isolators, CT / PT parts, lightning arresters, fuses and breaker components.
On requestSpares for low-voltage switchgear: breakers, contactors, trip units, auxiliaries, busbar parts and indicating devices.
On requestSpares for medium-voltage switchgear: vacuum interrupters, breaker mechanisms, coils, relays and auxiliaries.
On requestSpares for variable-frequency drives: power modules, capacitors, cooling fans, control cards and keypads.
On requestNo products match your filters. or ask our engineers.
Spares keep an existing plant running when original equipment is ageing or a manufacturer has stopped support. This range covers VFD spares, drive panel spares, MV panel spares, LV panel spares, substation equipment spares, motor spares and relays, so a single enquiry can cover a mixed list from one plant shutdown.
Buying spares is different from buying new equipment, because compatibility is the real risk. A breaker closing coil, a drive control card or a protection relay has to match the original in voltage, terminal layout, firmware and sometimes mechanical dimensions. Part numbers on the old unit are the quickest route to a correct match, and a photo of the nameplate and the failed part saves several rounds of questions.
Send the following with your enquiry:
If the failure points to a wider problem, the replacement may be better handled as a retrofit of the whole switchgear component. For drive-related failures, see drives and motor starters. Spares for medium-voltage equipment should be installed by qualified personnel under a safe isolation procedure.
Note the make, model, serial number and any part number on the failed item, and photograph the nameplate and the part in place. Voltage, current and mounting details must match. For obsolete equipment, a compatible replacement or retrofit unit may be offered, which should be approved by your maintenance engineer before use.
Not always. Where the original is no longer made, an equivalent part may be offered that matches the electrical rating and fit but differs in make or appearance. The enquiry should say whether an exact match is mandatory or an equivalent is acceptable, so the supplier can respond with the right options.
Cooling fans, DC bus capacitors, control cards and power modules are the common wear or failure items, and fans and capacitors are life-limited by temperature and running hours. Regular cleaning of heat sinks and filters, and checking ambient temperature, extends their life. Repair versus replace decisions depend on the drive age and spare availability.
Only after checking that the replacement matches the protection functions, ratings, burden, contact arrangement and communication, and that settings can be transferred. A change of relay usually needs re-testing and revised settings. Have a qualified protection engineer approve the replacement and commission it.
Common candidates are items that stop production when they fail and have a long lead time to obtain, such as drive control cards, breaker coils and trip units, protection relays and contactor coils. A criticality review of your own plant, with maintenance history, is the best way to decide quantities.