800V LT Panel
Low-voltage panels rated for 800 V class solar and inverter duty.
On request- StandardIEC 61439
- Voltage ClassLT, up to 800 V class

Download specification sheet (PDF)
Combined AC and DC distribution boards that protect and isolate the DC input and AC output of a solar inverter.
Made to order against your specification. Fill what you know; our engineers will confirm the rest.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: solar ACDB and DCDB box, ACDB DCDB for solar system, solar combiner box, solar AC DC distribution box, inverter protection box, solar DC and AC distribution board
This combined board puts the DC input protection and the AC output protection of one inverter in a single enclosure, which suits small rooftop and hybrid systems. Because it serves one inverter, start from that inverter's datasheet.
If you have several inverters, separate boards or a combiner box will be more suitable. For single-phase inverters see single-phase grid-tied inverters, or browse solar inverters and PCUs for the full range. Use the solar calculator to size strings, and have the final design checked by a competent engineer.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
For a single inverter in a small rooftop or hybrid system, where the DC and AC protection can sit in one enclosure. Larger plants with several inverters usually use separate boards or combiner boxes. Check the board is rated for the inverter's maximum DC input voltage.
Take the inverter's rated AC output current, add the design margin, and select a breaker and cable for that value. For a 5 kW single-phase inverter at 230 V the current is about 21.7 A.
In most solar systems yes, because long DC cable runs and exposed arrays pick up induced surges. Include a DC SPD rated for the system voltage and check the inverter manual. Place the SPD close to the inverter input with short earth leads so that it works well.
DCDB stands for DC Distribution Board. It combines the DC outputs of the PV strings and provides protection and isolation before they reach the inverter. It normally holds fuses, an isolator and surge protection.
ACDB stands for AC Distribution Board. It is placed on the AC output side of the inverter and provides protection and isolation before the power goes to the plant supply. It normally holds breakers and metering.
If the plant has several strings, a combiner or junction box is normally used to bring them together into fewer cables and to protect each string. The need depends on the number of strings and the inverter inputs, so check against your design.
Send the inverter rating, number of strings and string current, DC voltage, AC output rating, protection and surge device needs, enclosure type and protection degree. SKE Bharat prepares the quotation within 24 hours.
| Product Type | ACDB / DCDB |
|---|---|
| Standard | IEC 61439, IEC 60364-7-712 |
| Voltage Class | DC and AC (LT) |
| Construction | Sheet-steel or polycarbonate |
| Protection Degree | IP54 - IP65 |
| Typical Use | Inverter-side protection |
Type 1 SPDs handle direct lightning current at the service entrance, Type 2 sit at distribution boards and Type 3 protect sensitive equipment. Here is where…
6 min readSolar & Energy EfficiencyArray junction box, DCDB, AC combiner box and ACDB each protect a different stage of a solar plant; here is what they contain and how to…