AC-side distribution boards that gather inverter outputs and connect them to the plant LV supply.

On request

Describe what you need

Made to order against your specification. Fill what you know; our engineers will confirm the rest.

WhatsApp

Representative image. The actual product, make and appearance depend on the supplier and your specification.

Overview

Also searched as: ACDB, solar ACDB, AC distribution panel, alternating current distribution board, inverter AC collection panel, AC distribution box

Typical applications

  • Solar inverter output collection
  • Grid-tied systems
  • Net-metering connections

Key features

  • MCCB / ACB incomer and outgoing
  • Surge protection
  • Metering provisions

Selection notes

The AC distribution board takes the outputs of the solar inverters and connects them to the plant's low-voltage supply. Unlike a combiner box that merges outputs, it also feeds onward circuits, so incomer and outgoing devices both need thought.

  • The incomer is sized from the total inverter AC current plus margin, and should carry the right short-circuit rating for the fault level at the point of connection.
  • Each inverter feeder needs its own protection and isolation.
  • Decide on earth leakage protection with your designer; some inverters have leakage characteristics that cause nuisance trips on ordinary devices.
  • Include metering provision such as a multifunction meter, and a surge protection device.
  • Label feeders clearly so that maintenance staff can isolate safely.

Check busbar rating, enclosure protection and ventilation for the site. If the requirement is purely to gather several inverters into one feeder, see the AC combiner box. Breakers are covered under MCCB and the meters under multifunction meters. Details should be confirmed against your single-line diagram.

To quote, please share

  • System size (kWp) and inverter details
  • String / array configuration and DC voltage
  • Number of inputs and outputs
  • Indoor / outdoor mounting and ambient
  • Monitoring and protection requirements

Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.

Frequently asked questions

What should an AC distribution board for solar include?

An incomer, a protected feeder for each inverter, busbars rated for the total current and fault level, a surge protection device, metering and clear labelling. Your single-line diagram decides the details. Provision for earthing and a sensible number of spare ways are also worth including.

Can ordinary earth-leakage devices be used with solar inverters?

Some inverters produce leakage currents that cause nuisance tripping or may need specific device types. Check the inverter manual and choose accordingly with your designer. Ask the inverter maker whether a particular leakage-device type is required.

How is the incomer rating chosen?

From the sum of the inverters' rated AC currents with the design margin, and checked against the grid fault level and cable rating. Confirm with your electrical designer. Also check that the cable and busbar can carry the same current for the required duty.

What is an AC distribution board?

An AC distribution board, or ACDB, is a board that receives the AC output of one or more inverters and connects it to the plant LV supply through protective devices. It provides isolation, protection and a point for metering.

What is the full form of ACDB?

ACDB stands for Alternating Current Distribution Board. In a solar plant it is placed after the inverters to gather their AC outputs, protect the circuits and pass the power on to the plant supply.

What is the difference between an ACDB and a DCDB?

A DCDB is on the DC side and collects the PV string inputs before the inverter. An ACDB is on the AC side and collects the inverter outputs. Each has its own protection devices suited to DC or AC.

What details are needed for an ACDB quotation?

Send the number and rating of inverters, incoming and outgoing current ratings, short circuit rating in kA, protection and metering needs, wall or floor mounting and protection degree. SKE Bharat prepares the quotation within 24 hours.

Technical specification

Product TypeSolar ACDB
StandardIEC 61439
Voltage ClassLT, 415 V
ConstructionSheet-steel, wall or floor
Protection DegreeIP54 - IP65
Typical UseInverter AC collection