800V LT Panel
Low-voltage panels rated for 800 V class solar and inverter duty.
On request- StandardIEC 61439
- Voltage ClassLT, up to 800 V class

Download specification sheet (PDF)
AC-side distribution boards that gather inverter outputs and connect them to the plant LV supply.
Made to order against your specification. Fill what you know; our engineers will confirm the rest.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: ACDB, solar ACDB, AC distribution panel, alternating current distribution board, inverter AC collection panel, AC distribution box
The AC distribution board takes the outputs of the solar inverters and connects them to the plant's low-voltage supply. Unlike a combiner box that merges outputs, it also feeds onward circuits, so incomer and outgoing devices both need thought.
Check busbar rating, enclosure protection and ventilation for the site. If the requirement is purely to gather several inverters into one feeder, see the AC combiner box. Breakers are covered under MCCB and the meters under multifunction meters. Details should be confirmed against your single-line diagram.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
An incomer, a protected feeder for each inverter, busbars rated for the total current and fault level, a surge protection device, metering and clear labelling. Your single-line diagram decides the details. Provision for earthing and a sensible number of spare ways are also worth including.
Some inverters produce leakage currents that cause nuisance tripping or may need specific device types. Check the inverter manual and choose accordingly with your designer. Ask the inverter maker whether a particular leakage-device type is required.
From the sum of the inverters' rated AC currents with the design margin, and checked against the grid fault level and cable rating. Confirm with your electrical designer. Also check that the cable and busbar can carry the same current for the required duty.
An AC distribution board, or ACDB, is a board that receives the AC output of one or more inverters and connects it to the plant LV supply through protective devices. It provides isolation, protection and a point for metering.
ACDB stands for Alternating Current Distribution Board. In a solar plant it is placed after the inverters to gather their AC outputs, protect the circuits and pass the power on to the plant supply.
A DCDB is on the DC side and collects the PV string inputs before the inverter. An ACDB is on the AC side and collects the inverter outputs. Each has its own protection devices suited to DC or AC.
Send the number and rating of inverters, incoming and outgoing current ratings, short circuit rating in kA, protection and metering needs, wall or floor mounting and protection degree. SKE Bharat prepares the quotation within 24 hours.
| Product Type | Solar ACDB |
|---|---|
| Standard | IEC 61439 |
| Voltage Class | LT, 415 V |
| Construction | Sheet-steel, wall or floor |
| Protection Degree | IP54 - IP65 |
| Typical Use | Inverter AC collection |
Type 1 SPDs handle direct lightning current at the service entrance, Type 2 sit at distribution boards and Type 3 protect sensitive equipment. Here is where…
6 min readSolar & Energy EfficiencyArray junction box, DCDB, AC combiner box and ACDB each protect a different stage of a solar plant; here is what they contain and how to…
6 min read