MCB (Miniature Circuit Breaker)
Miniature circuit breakers for overload and short-circuit protection of final circuits in distribution boards.
On request- StandardIS/IEC 60898-1 (domestic), IEC 60947-2 (industrial)

Download specification sheet (PDF)
Air circuit breakers for main incomers and bus-couplers of LT switchboards at high current ratings.
Every field is optional - tell us what you know and we will confirm the rest in the quotation.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: ACB breaker, air circuit breaker, ACB for LT panel, main incomer breaker, LT incomer ACB, drawout ACB
Start with the frame current and breaking capacity. For an ACB, look at rated current, ultimate breaking capacity Icu, service breaking capacity Ics and the short-time withstand Icw, since a main incomer must stay closed long enough for downstream devices to clear a fault. Confirm all against the fault level at the board.
Mistakes: using only the rated current to choose, forgetting temperature derating inside a hot enclosure, and skipping a selectivity study. Settings should be set by an engineer from a coordination plan. For outgoing feeders, see MCCBs, and for complete boards see switchgear panels.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
Icu is the ultimate breaking capacity, the highest fault current the breaker can interrupt, after which it may not be usable again. Ics is the service breaking capacity, a percentage of Icu after which the breaker should remain in service. Ics matters for continuity.
It is the current an ACB can carry for a short time, such as one second, without opening, allowing downstream breakers to clear a fault first. This supports selectivity in the main incomer. It must exceed the fault level at the busbar.
ACB stands for Air Circuit Breaker. It is a low-voltage circuit breaker that interrupts current in air and is used as the main incomer or bus-coupler in LT switchboards at high current ratings.
In normal service the main contacts carry the load current. On an overload or short circuit the trip unit senses the fault and opens the contacts. The arc that forms is drawn into arc chutes, where it is cooled, split and extinguished in air.
ACBs are made in fixed and drawout versions, with 3 or 4 poles and different trip units. Choose by rated current, breaking capacity in kA at your installation, number of poles, release type and the auxiliary supply available.
Send the rated current, 3 or 4 poles, required breaking capacity in kA, fixed or drawout, protection functions needed in the trip unit, control voltage and accessories such as shunt trip or closing coil. SKE Bharat sends a quotation within 24 hours.
| Product Type | Air circuit breaker |
|---|---|
| Standard | IEC 60947-2 |
| Selection Basis | Current rating, poles, breaking capacity (kA), fixed or drawout, release type, auxiliary supply |
| Typical Use | Main incomers and bus-couplers in LT switchgear |
A step-by-step method to size a 11 kV/415 V transformer for a factory or building, with a worked example, standard kVA ratings and the mistakes that…
6 min readSwitchgear, Panels & ProtectionMCB, MCCB and ACB overlap in the middle of their ranges. This guide compares them on current, fault rating, trip settings and use, and shows how…
6 min readPumps, Cables & Buying GuidesA plain overview of how GeM works for electrical equipment, for government buyers and for suppliers, with tips on specifications and bid documents.
6 min read