ACB (Air Circuit Breaker)
ACB (Air Circuit Breaker)

Download specification sheet (PDF)

Circuit BreakersSKU SKE-SWC-004

ACB (Air Circuit Breaker)

Air circuit breakers for main incomers and bus-couplers of LT switchboards at high current ratings.

On request

Choose your specification

Every field is optional - tell us what you know and we will confirm the rest in the quotation.

WhatsApp

Representative image. The actual product, make and appearance depend on the supplier and your specification.

Overview

Also searched as: ACB breaker, air circuit breaker, ACB for LT panel, main incomer breaker, LT incomer ACB, drawout ACB

Typical applications

  • PCC and main LT panels
  • Industrial plants and substations
  • Generator incomers

Key features

  • Drawout construction for maintenance
  • Electronic release with protection settings
  • Communication-ready versions

Selection notes

Start with the frame current and breaking capacity. For an ACB, look at rated current, ultimate breaking capacity Icu, service breaking capacity Ics and the short-time withstand Icw, since a main incomer must stay closed long enough for downstream devices to clear a fault. Confirm all against the fault level at the board.

  • Poles: three-pole or four-pole depends on whether the neutral must be switched or protected, which relates to the supply and earthing scheme.
  • Trip unit: electronic releases offer long-time, short-time, instantaneous and earth-fault settings; choose adjustable ranges that allow selectivity with downstream MCCBs.
  • Drawout: drawout types allow isolation and testing without disconnecting cables.
  • Accessories: shunt trip, undervoltage release, closing coil and spring-charge motor voltages must be specified, and the number of auxiliary contacts counted.

Mistakes: using only the rated current to choose, forgetting temperature derating inside a hot enclosure, and skipping a selectivity study. Settings should be set by an engineer from a coordination plan. For outgoing feeders, see MCCBs, and for complete boards see switchgear panels.

To quote, please share

  • Rating (current / voltage / capacity) and quantity
  • Standard and approvals required
  • Application and installation environment
  • Preferred make, if any (we confirm what we can supply)
  • Datasheet or drawing reference, if you have one

Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.

Frequently asked questions

What is the difference between Icu and Ics on an ACB?

Icu is the ultimate breaking capacity, the highest fault current the breaker can interrupt, after which it may not be usable again. Ics is the service breaking capacity, a percentage of Icu after which the breaker should remain in service. Ics matters for continuity.

Why is short-time withstand current (Icw) important?

It is the current an ACB can carry for a short time, such as one second, without opening, allowing downstream breakers to clear a fault first. This supports selectivity in the main incomer. It must exceed the fault level at the busbar.

What is the full form of ACB breaker?

ACB stands for Air Circuit Breaker. It is a low-voltage circuit breaker that interrupts current in air and is used as the main incomer or bus-coupler in LT switchboards at high current ratings.

How does an ACB work?

In normal service the main contacts carry the load current. On an overload or short circuit the trip unit senses the fault and opens the contacts. The arc that forms is drawn into arc chutes, where it is cooled, split and extinguished in air.

What are the types of ACB and how do I choose one?

ACBs are made in fixed and drawout versions, with 3 or 4 poles and different trip units. Choose by rated current, breaking capacity in kA at your installation, number of poles, release type and the auxiliary supply available.

What should I send for an ACB quotation?

Send the rated current, 3 or 4 poles, required breaking capacity in kA, fixed or drawout, protection functions needed in the trip unit, control voltage and accessories such as shunt trip or closing coil. SKE Bharat sends a quotation within 24 hours.

Technical specification

Product TypeAir circuit breaker
StandardIEC 60947-2
Selection BasisCurrent rating, poles, breaking capacity (kA), fixed or drawout, release type, auxiliary supply
Typical UseMain incomers and bus-couplers in LT switchgear