Choose first by frame size and breaking capacity, then fit the trip unit. Check Icu and Ics against the prospective fault at the point of installation; a breaker rated too low can fail dangerously on a fault. Rated current should suit the cable and load, noting that the rating is quoted at a reference ambient and may need derating inside a hot panel.
Typical errors: ignoring terminal size for large cables, mixing breaker makes in a way that breaks discrimination, and neglecting the earth-fault protection setting. Use selectivity tables from the manufacturer. Upstream, look at an ACB; for final circuits, an MCB.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
Thermal-magnetic units use a bimetal for overload and a magnet for short circuit, with limited adjustment. Electronic units measure current digitally and allow adjustable overload, short-time and earth-fault settings, which improves coordination in larger systems.
Not always. A general feeder MCCB may trip on motor starting current or fail to protect against overload. Use a motor-duty MCCB or a magnetic-only MCCB with an overload relay, sized for the motor's starting characteristics.
MCCB stands for Moulded Case Circuit Breaker. It is housed in a moulded insulating case and protects a circuit against overload and short circuit. It is used for feeders, incomers and motor circuits in LT panels.
An MCB is used for lower currents in final circuits, up to about 125 A, with fixed trip settings. An MCCB is used for higher currents, offers higher breaking capacity, and many models have adjustable trip settings.
A thermal element, usually a bimetal, trips the breaker on a sustained overload, and a magnetic element trips it instantly on a short circuit. Electronic trip units use sensors and a processor to give adjustable settings.
Choose the current rating, number of poles, breaking capacity in kA at the system voltage, trip unit type and frame size, and check coordination with upstream and downstream devices. Send these details for a quotation.
| Product Type | Moulded case circuit breaker |
|---|---|
| Standard | IEC 60947-2 |
| Selection Basis | Frame size, current rating, poles, breaking capacity (kA), trip unit (thermal-magnetic / electronic) |
| Typical Use | Feeders, incomers and motor circuits in LT panels |