Power Capacitors
LT power capacitors for power-factor correction, in cylindrical and box constructions.
On request- StandardIS 13340, IEC 60831

Download specification sheet (PDF)
Automatic power-factor controllers and detuning reactors used in APFC panels.
Every field is optional - tell us what you know and we will confirm the rest in the quotation.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: APFC relay, automatic power factor controller, power factor controller, detuned reactor, APFC panel reactor, capacitor detuning reactor
The controller decides how well the bank follows the load, and the reactor decides whether the capacitors survive harmonics. Choose the number of steps to suit load variation; more, smaller steps track a changing load better and avoid over-correction. Check that the controller supports the CT secondary (1 A or 5 A) you intend to use, and that the CT sits upstream of both the load and the capacitor bank so it sees the net current.
Get a harmonic measurement before finalising. Related components include power capacitors and the finished APFC panel. Use the power factor calculator for kVAr sizing.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
Use them when non-linear loads such as drives, UPS, rectifiers or LED lighting make up a large part of the load, or when harmonic measurements show a risk of resonance with plain capacitors. A site harmonic study gives the reactor percentage; do not guess.
Common causes are a wrong CT ratio or CT location, a wrongly set C/K value, too small a step compared with the load swing, or a very short time delay. Check the CT wiring and settings before suspecting the controller itself.
An APFC controller reads the power factor of the supply through a CT and switches capacitor steps in or out to bring it to the set value. It is the control unit inside an automatic power factor correction panel.
A detuned reactor is connected in series with a capacitor so that the combination does not resonate with harmonics in the system. It protects the capacitors and the supply when non-linear loads such as drives are present. The detuning percentage is chosen to suit the system.
For the controller, choose the number of steps and the CT ratio and supply it is to work on. For the reactor, choose the detuning percentage and kVAr to match the capacitor step and supply. Harmonic levels at the site should guide the choice.
Send the number of steps, CT ratio, supply voltage, capacitor kVAr per step, detuning percentage required and the quantity. A site harmonic report helps if available. SKE Bharat will prepare a quotation from these details.
| Product Type | Power-factor controller / reactor |
|---|---|
| Standard | IEC 61000-6, IS 5553 (reactors) |
| Selection Basis | Number of steps, CT ratio, detuning % (e.g. 5.67 / 7 %), reactor kVAr, supply |
| Typical Use | Switching and protecting capacitor banks |