Drive Panel Spares
Spares for drive and control panels: contactors, relays, fuses, power supplies, fans and control components.
On request- Spare TypePanel components
- Applies ToDrive and control panels
- Selection BasisMake, model and part number

Download specification sheet (PDF)
Spares for low-voltage switchgear: breakers, contactors, trip units, auxiliaries, busbar parts and indicating devices.
Every field is optional - tell us what you know and we will confirm the rest in the quotation.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: LV switchgear spares, ACB spares, MCCB spares, LT panel spare parts, PCC and MCC panel spares
In low-voltage gear the common failures are worn contacts, burnt coils and tripped or damaged trip units. A like-for-like spare is the safest approach, so begin with the existing device's nameplate and frame size.
After replacing a breaker or trip unit, reset the settings to the coordination study values, not factory defaults. Where a breaker is end-of-life, review whether a current model such as an ACB or MCCB is a better route. Isolate and verify dead before opening any panel; leave work to qualified personnel.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
No. Trip units are designed for a particular breaker frame and its sensors, so they should only be used with the exact frame and make specified by the manufacturer. A mismatched unit can leave the breaker without correct protection or fail to trip, which is a safety risk.
The coil voltage, frequency (AC or DC), the contactor make and model, and any auxiliary contact needs. Using the wrong coil voltage either burns the coil or prevents closing. State also whether you need extra auxiliary contacts for interlocks and indication.
Set current and time settings to the values from your protection coordination study, not the factory default. Record the settings and test the breaker where facilities allow. Photograph or record the settings before removing the old unit and keep the record in the maintenance file.
The range covers breakers, contactors, trip units, auxiliaries, busbar parts and indicating devices for ACB, MCCB, MCC and PCC panels. Availability depends on the make, model and frame size, so confirm these first.
Both are low-voltage circuit breakers. An ACB is an air circuit breaker used on larger incoming and bus-coupler duties and is built for maintenance. An MCCB is a moulded case breaker used on feeders and smaller ratings.
Send the make, model, frame size and rated current of the breaker or contactor, its serial number, the part needed and a photo of the nameplate. This matches the spare to your panel.
SKE Bharat is a supplier based in Rajaji Nagar, Bangalore, supplying across India. Quotations are prepared from the ratings you send, so share your requirement and we will respond within 24 hours.
| Spare Type | LV switchgear parts |
|---|---|
| Applies To | ACB, MCCB, MCC and PCC panels |
| Selection Basis | Make, model and frame size |
| Supply | Ex-stock or sourced to order |