Switchgear LV Panel Spares
Switchgear LV Panel Spares

Download specification sheet (PDF)

SparesSKU SKE-SPR-005

Switchgear LV Panel Spares

Spares for low-voltage switchgear: breakers, contactors, trip units, auxiliaries, busbar parts and indicating devices.

On request

Choose your specification

Every field is optional - tell us what you know and we will confirm the rest in the quotation.

WhatsApp

Representative image. The actual product, make and appearance depend on the supplier and your specification.

Overview

Also searched as: LV switchgear spares, ACB spares, MCCB spares, LT panel spare parts, PCC and MCC panel spares

Typical applications

  • Breaker and contactor replacement
  • Panel retrofits
  • Planned maintenance stock

Key features

  • Major-make compatible
  • Trip units and coils available
  • Retrofit guidance

Selection notes

In low-voltage gear the common failures are worn contacts, burnt coils and tripped or damaged trip units. A like-for-like spare is the safest approach, so begin with the existing device's nameplate and frame size.

  • Breakers: note the frame rating, number of poles, breaking capacity and fixed or draw-out form. A replacement breaker may need the same mounting and busbar connections.
  • Trip units: they are matched to the breaker frame and current transformers; do not mix across makes or frames.
  • Contactors and coils: match the coil voltage and frequency, and the rated operational current for the load category.
  • Busbar parts and insulators: check the busbar size and the spacing.

After replacing a breaker or trip unit, reset the settings to the coordination study values, not factory defaults. Where a breaker is end-of-life, review whether a current model such as an ACB or MCCB is a better route. Isolate and verify dead before opening any panel; leave work to qualified personnel.

To quote, please share

  • Make, model and serial / nameplate details
  • Part number or a photograph of the part
  • Quantity and urgency
  • Voltage / rating of the equipment
  • Whether OEM-original or compatible parts are acceptable

Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.

Frequently asked questions

Can I use a trip unit from a different breaker frame?

No. Trip units are designed for a particular breaker frame and its sensors, so they should only be used with the exact frame and make specified by the manufacturer. A mismatched unit can leave the breaker without correct protection or fail to trip, which is a safety risk.

What do I need to give for a contactor coil?

The coil voltage, frequency (AC or DC), the contactor make and model, and any auxiliary contact needs. Using the wrong coil voltage either burns the coil or prevents closing. State also whether you need extra auxiliary contacts for interlocks and indication.

What should be set after replacing a breaker?

Set current and time settings to the values from your protection coordination study, not the factory default. Record the settings and test the breaker where facilities allow. Photograph or record the settings before removing the old unit and keep the record in the maintenance file.

What spares are available for LV switchgear?

The range covers breakers, contactors, trip units, auxiliaries, busbar parts and indicating devices for ACB, MCCB, MCC and PCC panels. Availability depends on the make, model and frame size, so confirm these first.

What is the difference between an ACB and an MCCB?

Both are low-voltage circuit breakers. An ACB is an air circuit breaker used on larger incoming and bus-coupler duties and is built for maintenance. An MCCB is a moulded case breaker used on feeders and smaller ratings.

What details are needed to order an LV switchgear spare?

Send the make, model, frame size and rated current of the breaker or contactor, its serial number, the part needed and a photo of the nameplate. This matches the spare to your panel.

Who supplies LV panel spares in Bangalore?

SKE Bharat is a supplier based in Rajaji Nagar, Bangalore, supplying across India. Quotations are prepared from the ratings you send, so share your requirement and we will respond within 24 hours.

Technical specification

Spare TypeLV switchgear parts
Applies ToACB, MCCB, MCC and PCC panels
Selection BasisMake, model and frame size
SupplyEx-stock or sourced to order