Overload relays and motor protection circuit breakers that protect motors against overload and phase loss.
Every field is optional - tell us what you know and we will confirm the rest in the quotation.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: thermal overload relay, overload relay for contactor, motor protection circuit breaker, MPCB, motor protection breaker, TOR relay
Choose the setting range so that the motor's full-load current from the nameplate falls inside it, ideally near the middle, then set the dial to that current. Relays that cover a wide range help when motors change, but a narrow range gives better resolution.
Mistakes: setting the relay to the breaker rating, using the wrong relay with a VFD, and ignoring the coordination between relay, contactor and short-circuit device. Confirm coordination data with the manufacturer. The usual pairing is a power contactor and an MCB or fuses upstream.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
Set it to the motor's full-load current from the nameplate, adjusted only if the manufacturer's data or site conditions require. Setting it higher to avoid nuisance trips hides real problems and risks damaging the motor.
An MPCB provides short-circuit, overload and phase-loss protection and manual isolation in one compact device, saving panel space and wiring. A thermal relay with fuses is flexible and lower cost per part but needs more components.
A thermal overload relay protects a motor from drawing too much current for too long. It heats up with the motor current and trips the contactor coil circuit if the overload continues, usually along with phase loss protection.
A thermal overload relay gives overload protection only and is used with a contactor and separate short circuit protection. An MPCB combines overload protection, short circuit protection and manual switching in one unit.
Use the motor full load current to pick a relay or MPCB whose adjustable current range covers it. Then check the trip class, the contactor it will pair with and whether you need phase failure protection.
Send the motor kW or HP rating, voltage, full load current, starter type such as DOL or star-delta, preferred trip class and make. Quotations are prepared from the details you send, so share your requirement and SKE Bharat will respond within 24 hours.
| Product Type | Overload relay / motor protection breaker |
|---|---|
| Standard | IEC 60947-4-1, IEC 60947-2 |
| Selection Basis | Motor full-load current range, trip class, contactor to pair with |
| Typical Use | Motor protection in starters |