Switchgear MV Panel Spares
Switchgear MV Panel Spares

Download specification sheet (PDF)

SparesSKU SKE-SPR-006

Switchgear MV Panel Spares

Spares for medium-voltage switchgear: vacuum interrupters, breaker mechanisms, coils, relays and auxiliaries.

On request

Choose your specification

Every field is optional - tell us what you know and we will confirm the rest in the quotation.

WhatsApp

Representative image. The actual product, make and appearance depend on the supplier and your specification.

Overview

Also searched as: MV switchgear spares, HT panel spares, VCB spares, vacuum circuit breaker spare parts, 11 kV panel spares

Typical applications

  • VCB overhaul
  • Replacement of coils and mechanisms
  • Planned shutdown spares

Key features

  • Rated to the panel and make
  • Mechanism and coil spares
  • Documentation on request

Selection notes

Medium-voltage spares are tied to the breaker or panel type, so identify the equipment before anything else: make, model, rated voltage, rated current, short-circuit rating and serial number from the nameplate. A part for a similar-looking breaker will often not fit or may not meet the duty.

  • Coils and motors: closing coil, trip coil and spring-charging motor are rated for a specific control voltage (for example a DC level) so read the value from the old part.
  • Vacuum interrupters: replacement is a specialist job needing travel and contact-gap checks afterwards, so ask the breaker maker's procedure.
  • Relays and auxiliaries: match CT secondary rating, auxiliary supply and contact arrangement.

Always isolate, prove dead and earth before working inside a panel; MV work must be done by a qualified person following your site safety rules. For complete breakers see vacuum circuit breakers, for protective relays see protection relays, and for low-voltage equivalents see LV switchgear spares. Keep a small stock of coils and auxiliary contacts for breakdown cover.

To quote, please share

  • Make, model and serial / nameplate details
  • Part number or a photograph of the part
  • Quantity and urgency
  • Voltage / rating of the equipment
  • Whether OEM-original or compatible parts are acceptable

Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.

Frequently asked questions

How do I identify the correct spare for an MV breaker?

Read the nameplate for make, type, rating and serial number, and note the part label or photograph the worn part. Coil voltage and mechanism type are critical details that decide compatibility. For older equipment, the maker's drawings or spare-parts list help confirm the exact part number.

When should a vacuum interrupter be replaced?

When contact wear exceeds the maker's limit, the vacuum is lost, or tests fail. The limits and test method come from the breaker manufacturer, so follow their procedure and use qualified personnel. Tests after replacement, such as vacuum integrity and contact resistance, are normally prescribed in the maker's manual.

Which spares should I keep in stock?

Common choices are closing and trip coils, spring-charging motors, auxiliary switches, and a few indicating and control components. The right list depends on breaker type and criticality, and your maintenance history is the best guide.

What spares are used in medium voltage switchgear?

Common spares include vacuum interrupters, breaker operating mechanisms, closing and trip coils, protection relays and auxiliary items. The list for your panel depends on the make and model of the breaker and panel.

What is a vacuum interrupter?

A vacuum interrupter is a sealed bottle in which the breaker contacts open inside a vacuum, so the arc is put out quickly when current is interrupted. It is the main part of a vacuum circuit breaker.

What details are needed to order MV panel spares?

Send the make, model and rating of the breaker or panel, the serial number, the voltage class, the part needed and a photo of the nameplate and the part. These details are required to match the part.

Which voltage range do these spares cover?

The range is listed for medium voltage panels from 3.3 kV to 33 kV. Availability depends on the make and model, so send your panel details and SKE Bharat will check what can be supplied or sourced.

Technical specification

Spare TypeMV switchgear parts
Applies To3.3 kV to 33 kV panels
Selection BasisMake, model and rating
SupplyEx-stock or sourced to order