Medium-voltage spares are tied to the breaker or panel type, so identify the equipment before anything else: make, model, rated voltage, rated current, short-circuit rating and serial number from the nameplate. A part for a similar-looking breaker will often not fit or may not meet the duty.
Always isolate, prove dead and earth before working inside a panel; MV work must be done by a qualified person following your site safety rules. For complete breakers see vacuum circuit breakers, for protective relays see protection relays, and for low-voltage equivalents see LV switchgear spares. Keep a small stock of coils and auxiliary contacts for breakdown cover.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
Read the nameplate for make, type, rating and serial number, and note the part label or photograph the worn part. Coil voltage and mechanism type are critical details that decide compatibility. For older equipment, the maker's drawings or spare-parts list help confirm the exact part number.
When contact wear exceeds the maker's limit, the vacuum is lost, or tests fail. The limits and test method come from the breaker manufacturer, so follow their procedure and use qualified personnel. Tests after replacement, such as vacuum integrity and contact resistance, are normally prescribed in the maker's manual.
Common choices are closing and trip coils, spring-charging motors, auxiliary switches, and a few indicating and control components. The right list depends on breaker type and criticality, and your maintenance history is the best guide.
Common spares include vacuum interrupters, breaker operating mechanisms, closing and trip coils, protection relays and auxiliary items. The list for your panel depends on the make and model of the breaker and panel.
A vacuum interrupter is a sealed bottle in which the breaker contacts open inside a vacuum, so the arc is put out quickly when current is interrupted. It is the main part of a vacuum circuit breaker.
Send the make, model and rating of the breaker or panel, the serial number, the voltage class, the part needed and a photo of the nameplate and the part. These details are required to match the part.
The range is listed for medium voltage panels from 3.3 kV to 33 kV. Availability depends on the make and model, so send your panel details and SKE Bharat will check what can be supplied or sourced.
| Spare Type | MV switchgear parts |
|---|---|
| Applies To | 3.3 kV to 33 kV panels |
| Selection Basis | Make, model and rating |
| Supply | Ex-stock or sourced to order |