Cable Lugs & Glands
Crimp lugs and cable glands for terminating power and control cables.
On request- StandardIS 8309 (lugs), IEC 62444 (glands)

Download specification sheet (PDF)
Multicore cables for control, interlock and signal wiring between panels, drives and field devices.
Every field is optional - tell us what you know and we will confirm the rest in the quotation.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: multicore control cable, PVC control cable, copper control cable, 1.1 kV control cable, interlock cable, control wiring cable
Choose core count and size from the circuit list, then add 10 to 20 percent spare cores for future changes and faults. For most control wiring a 1.5 mm squared copper conductor suffices; use larger conductors, such as 2.5 mm squared, for long runs to contactor coils or when voltage drop at the coil matters.
Common errors are under-sizing for coil pull-in current over long distance, mixing AC and DC signals in a single cable without review, and failing to derate when many cables are bunched. Compare with instrumentation cables for signals, and use power cables for the main supply.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
Many designers allow 10 to 20 percent spare cores to cover faults and later modifications, though the exact figure follows the project specification. Add the spare cores to the total core count you order, not as an afterthought.
When control wiring runs close to power or VFD cables, or when signals are sensitive to interference. The screen reduces induced noise and should be earthed properly. For ordinary on-off signals inside protected routes, an unscreened cable is often enough.
A control cable is a multicore cable used to carry control and interlock signals between panels, drives and field devices. It is not meant for carrying main power to large loads.
A power cable is sized to carry load current to equipment and usually has fewer, larger cores. A control cable has many smaller cores for control signals, such as start, stop and status, between devices.
They differ by insulation, PVC or XLPE, by number of cores, by conductor size and by whether they are armoured or unarmoured. The range covers copper multicore control cables at 1.1 kV.
Send the number of cores, conductor size in sq mm, insulation type, armoured or unarmoured construction, length and make preference. Quotations are prepared from the details you send, so share your requirement and SKE Bharat will respond within 24 hours.
| Cable Type | Control cable, multicore |
|---|---|
| Standard | IS 1554 (PVC, 1.1 kV) |
| Conductor | Copper |
| Insulation | PVC or XLPE |
| Voltage Grade | 1.1 kV |
| Typical Use | Control and interlock wiring |