DC Drives
Thyristor DC drives for speed control of DC motors in rolling mills, cranes and process lines.
On request- StandardIEC 61800-1

Download specification sheet (PDF)
Electronic starters that ramp motor voltage for smooth starting and reduced mechanical and electrical stress.
Every field is optional - tell us what you know and we will confirm the rest in the quotation.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: soft starter, motor soft starter, soft starter for 3 phase motor, electronic motor starter, soft start for motor, reduced voltage motor starter
A soft starter reduces starting current and mechanical shock but does not control running speed; if you need speed variation, look at a VFD instead. Select by motor full-load current and the starting duty: a lightly loaded centrifugal pump is an easy start, while crushers, compressors with load, or high-inertia fans need a starter rated for heavy duty with a longer ramp.
A common mistake is selecting by kW and forgetting that a long starting time (for example, 30 seconds) heats the starter far more than a quick start. For very large HT motors see medium voltage soft starters. For fuse and breaker pairing see HRC fuses.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
Choose a VFD if you need speed control, energy saving through speed reduction, or a very low starting current at the motor terminals. A soft starter is simpler and cheaper where the motor runs at full speed and only the start itself needs softening, and where the extra drive electronics are not justified.
Not always, but a bypass removes continuous heat from the thyristors, improves efficiency and extends life, especially in enclosed panels. Many units include it internally. Check whether the protection functions remain active in bypass mode, as this differs between models.
A soft starter is an electronic device that raises the voltage applied to an AC induction motor gradually during starting. This reduces the starting current and the mechanical shock on the motor, coupling and driven machine compared with direct-on-line starting.
A soft starter controls the motor only while starting and stopping, then the motor runs at full line speed, often through a bypass contactor. A VFD controls speed continuously by changing frequency and voltage. Choose a VFD when speed control is required.
Select by motor kW or current and supply voltage. Then consider the starting duty, such as the type of load, ramp time and starts per hour, whether a bypass contactor is needed, and the protection functions you want built in.
SKE Bharat is a supplier based in Rajaji Nagar, Bangalore, supplying across India. Quotations are prepared from the ratings you send, such as motor kW, supply voltage and application. A quotation is sent within 24 hours.
| Product Type | Soft starter |
|---|---|
| Standard | IEC 60947-4-2 |
| Selection Basis | Motor kW / current, supply voltage, start duty, bypass, protection functions |
| Typical Use | Smooth starting of motors |