17.5 to 33 KV HT Panels
Indoor HT switchgear panels for 17.5 kV to 33 kV class distribution.
On request- StandardIEC 62271-200
- Voltage Class17.5 kV - 33 kV

Download specification sheet (PDF)
Medium-voltage solid-state soft starters for smooth acceleration of large HV motors.
Every field is optional - tell us what you know and we will confirm the rest in the quotation.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: MV soft starter, medium voltage motor starter, high voltage motor soft starter, MV soft starter panel, HV motor soft starter, medium voltage soft start panel
A medium-voltage soft starter limits starting current and torque on a large HV motor, but it does not remove the need to check the supply. Begin with motor voltage, kW, full-load current and the load's starting torque curve; a pump with a closed valve needs far less than a loaded crusher.
Typical mistakes: sizing only by kW, ignoring frequent-start duty, and forgetting the ventilation needed in the panel room. If you also need speed control, compare with a drive or starter. Final selection should be confirmed with a qualified engineer using your motor datasheet.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
When the starting current dips the supply voltage beyond what the grid, generator or other loads can tolerate, or when the mechanical shock of a full-voltage start damages couplings and belts. If the supply is strong and the load tolerates it, DOL with proper protection is simpler.
No. A soft starter only ramps voltage during starting and then runs the motor at line speed. It cannot control speed or save energy on variable loads. Choose a VFD if the process needs speed regulation, and a soft starter if you only need a gentle start.
It is a solid-state starter for large high voltage motors, usually in the 3.3 kV to 11 kV range. It raises the voltage gradually at start, so the motor accelerates smoothly and the starting current and mechanical shock are reduced.
A direct on line start draws a very high current and puts stress on the motor, the coupling and the supply. A soft starter limits the starting current and torque and gives a smooth start of the driven equipment.
A soft starter only controls voltage during starting and stopping, and then the motor runs at full speed. A variable frequency drive changes the frequency and so controls the speed continuously during running as well.
Send the motor kW or HP, voltage, full load current, starting duty and load type, supply fault level, bypass and protection needs and make preference. Price depends on rating and make, so send details for a quotation.
| Panel Type | MV soft starter panel |
|---|---|
| Standard | IEC 60947-4-2 / IEC 62271 |
| Voltage Class | 3.3 kV - 11 kV |
| Construction | Metal-enclosed |
| Protection Degree | IP4X (typical) |
| Typical Use | HV motor soft starting |