Battery Chargers & DC Power Supplies
Float-and-boost chargers and DC power supplies for stationary battery banks.
On request- StandardIEC 62040-3 (UPS), IEC 61204 (power supplies)

Manufacturer brochure · Manufacturer product page
Download specification sheet (PDF)
Low-maintenance flooded tubular 2 V cells (300-1000 Ah) for larger off-grid and hybrid solar plants.
Every field is optional - tell us what you know and we will confirm the rest in the quotation.
Also searched as: Exide Solatubular LMXT, Exide LMXT 2 V cell, Exide 2 V tubular battery for solar, Exide low maintenance 2 V solar cell, Exide 2 V 1000 Ah solar battery
| Model | Voltage | Capacity | Cell weight with acid | Dimensions (L x W x H) |
|---|---|---|---|---|
| LMXT300 | 2 V | 300 Ah (C10 at 27 C) | 21 kg | 125 x 158 x 543 mm |
| LMXT400 | 2 V | 400 Ah (C10 at 27 C) | 27 kg | 125 x 158 x 699 mm |
| LMXT500 | 2 V | 500 Ah (C10 at 27 C) | 37 kg | 173 x 158 x 699 mm |
| LMXT550 | 2 V | 550 Ah (C10 at 27 C) | 39 kg | 173 x 158 x 699 mm |
| LMXT600 | 2 V | 600 Ah (C10 at 27 C) | 40 kg | 173 x 158 x 699 mm |
| LMXT650 | 2 V | 650 Ah (C10 at 27 C) | 41 kg | 173 x 158 x 699 mm |
| LMXT700 | 2 V | 700 Ah (C10 at 27 C) | 51 kg | 205 x 158 x 753 mm |
| LMXT750 | 2 V | 750 Ah (C10 at 27 C) | 52 kg | 205 x 158 x 753 mm |
| LMXT800 | 2 V | 800 Ah (C10 at 27 C) | 53 kg | 205 x 158 x 753 mm |
| LMXT850 | 2 V | 850 Ah (C10 at 27 C) | 65 kg | 416 x 172 x 535 mm |
| LMXT900 | 2 V | 900 Ah (C10 at 27 C) | 67 kg | 416 x 171 x 535 mm |
| LMXT1000 | 2 V | 1000 Ah (C10 at 27 C) | 72 kg | 416 x 171 x 535 mm |
Ratings are as published by the manufacturer. We confirm the exact model, ratings and warranty in your quotation.
Individual 2 V cells are connected in series to form the bank voltage, such as 24 cells for a 48 V bank. They are easier to handle at large capacities and a single weak cell can be replaced. This range covers 300 to 1000 Ah.
The cells are flooded tubular, so the electrolyte level should be checked at intervals and topped up with distilled water, but less often than in a conventional flooded battery. Follow the maker's maintenance schedule.
Divide the bank voltage by 2. A 48 V bank needs 24 cells and a 110 V bank needs 55 cells in series. Add parallel strings if more Ah is needed. The PCU or inverter voltage fixes the bank voltage.
Send the bank voltage, required Ah, quantity of cells, and whether the plant is off-grid or hybrid. Price depends on model, rating, make and quantity, so send details for a quotation.
| Brand | Exide |
|---|---|
| Product Type | Solar Storage Batteries |