17.5 to 33 KV HT Panels
Indoor HT switchgear panels for 17.5 kV to 33 kV class distribution.
On request- StandardIEC 62271-200
- Voltage Class17.5 kV - 33 kV

Download specification sheet (PDF)
Medium-voltage switchgear for plant incomers, feeders and HV motors.
Made to order against your specification. Fill what you know; our engineers will confirm the rest.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: MV switchgear, medium voltage switchgear panel, high voltage panels, HT panel, medium voltage panel board, MV switchgear panel
Medium-voltage panels are specified from the system study, so collect fault level and incomer details before choosing configuration. The breaking capacity and short-time withstand rating (usually in kA for 1 or 3 seconds) must exceed the prospective fault current at that bus, with margin.
A frequent mistake is choosing the busbar rating from the transformer rating alone and forgetting future expansion. Check that the cable box has room for the number of cores and the termination kits you plan to use. Operating voltage should match your supply: see the 3.3 kV to 11 kV panels or 17.5 to 33 kV panels if you need a defined class.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
Share the single-line diagram, system voltage, fault level in kA, busbar current, number of incomers and feeders, switching device preference and relay or metering needs. Without the fault level, breaker and busbar ratings cannot be confirmed, so request it from your DISCOM or plant electrical study.
Often yes, using contactor or breaker feeders built for motor duty. The decision depends on start frequency and fault level, since contactors have lower breaking capacity and need back-up fuses. Describe motor kW, voltage and starts per hour so the right feeder type can be proposed.
Medium voltage generally refers to system voltages above low voltage and up to about 33 kV in industrial practice. The exact definition varies by standard, and in plants it covers voltages such as 3.3 kV, 6.6 kV, 11 kV and 33 kV.
It is used to receive supply at plant level, distribute it through feeders and start or protect large high voltage motors. It houses breakers, busbars, instrument transformers and protection relays in a metal-enclosed assembly.
Medium voltage switchgear can be air insulated or gas insulated, and the breaker can be vacuum type or another type. Panels can be fixed or withdrawable. The choice depends on the voltage, fault level and space available.
Send the system voltage, current rating, short circuit rating in kA, number of incomers and feeders, protection relay needs, indoor or outdoor use and make preference. Price depends on rating, make and quantity, so share details for a quotation.
| Panel Type | MV switchgear |
|---|---|
| Standard | IEC 62271-200 |
| Voltage Class | 3.3 kV - 33 kV |
| Construction | Metal-enclosed |
| Protection Degree | IP4X (typical) |
| Typical Use | MV distribution and motors |