3.3 KV to 11 KV MV Panels
Metal-enclosed medium-voltage switchgear for motor starting and distribution from 3.3 kV to 11 kV.
On request- StandardIEC 62271-200
- Voltage Class3.3 kV - 11 kV

Download specification sheet (PDF)
Indoor HT switchgear panels for 17.5 kV to 33 kV class distribution.
Made to order against your specification. Fill what you know; our engineers will confirm the rest.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: HT panel, 33 kV HT panel, 17.5 kV HT switchgear, HT switchgear panel, 33 kV switchgear, indoor HT panel
At 17.5 to 33 kV class, the first thing to confirm is the system voltage and insulation level, since an 11 kV board cannot be stretched to 33 kV. Gather the highest system voltage, fault level and the number of incomers and feeders.
Mistakes include ignoring clearance and room height for HT equipment, no plan for cable termination space, and leaving the earthing and interlock scheme vague. Operating personnel safety matters, so ask for internal-arc options if staff will be in front of the board. Compare with 3.3 to 11 kV panels if your voltage is lower. A qualified engineer should approve the design.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
Share system voltage, fault level, incomer and feeder count, busbar current, CT and PT ratios, protection relay functions, metering needs and whether the room is indoor with limited height. Include any DISCOM or utility specification the board must follow.
They are commonly used for collection and grid connection at such plants. The exact configuration depends on the grid utility's requirements and your collector design, so share the single-line diagram and any utility technical conditions.
An HT panel is a high tension switchgear panel for higher distribution voltages, here in the 17.5 kV to 33 kV class. It houses breakers, busbars, instrument transformers and protection relays to receive, distribute and protect the supply.
This range covers the 17.5 kV to 33 kV class, built as metal-enclosed, compartmentalised indoor switchgear to IEC 62271-200. Send your exact system voltage so the correct rating is selected.
They are used at utility and plant HT incomers, where the supply arrives at 33 kV or similar level and is distributed to transformers or further feeders. They are typically installed in a switchgear room.
Send the system voltage, current rating, short circuit rating in kA, number of incomers and feeders, protection and metering needs, single line diagram and make preference. Price depends on rating, make and quantity, so share details for a quotation.
| Panel Type | HT switchgear |
|---|---|
| Standard | IEC 62271-200 |
| Voltage Class | 17.5 kV - 33 kV |
| Construction | Metal-enclosed, compartmentalised |
| Protection Degree | IP4X (typical) |
| Typical Use | Utility and plant HT incomers |