17.5 to 33 KV HT Panels
Indoor HT switchgear panels for 17.5 kV to 33 kV class distribution.
On request- StandardIEC 62271-200
- Voltage Class17.5 kV - 33 kV

Download specification sheet (PDF)
Metal-enclosed medium-voltage switchgear for motor starting and distribution from 3.3 kV to 11 kV.
Made to order against your specification. Fill what you know; our engineers will confirm the rest.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: MV panel, 11 kV MV panel, 3.3 kV switchgear, 11 kV switchgear, HV motor starter panel, medium voltage switchgear 11 kV
For 3.3 to 11 kV boards, start by listing what each panel will do: incomer, bus section, transformer feeder or motor starter. Each function needs a different switching device and relay set.
Typical mistakes are specifying the busbar by connected load rather than diversified maximum demand with growth, ignoring the cable box dimensions, and leaving relay settings to commissioning. Provide a relay schedule early. Cable termination kits and the number of cores per phase affect the compartment depth, so give the cable details. Voltage class should be confirmed: 3.3, 6.6 and 11 kV boards can look alike but are not interchangeable. For general guidance, see medium voltage panels.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
Yes. A lineup can mix incomer, transformer feeder and motor starter panels, each with the switching device and relay suited to the duty. State the function, rating and starting method for every panel so the lineup can be arranged logically.
Use a breaker where fault clearing and flexible protection settings matter, such as incomers and feeders. Use contactor panels with back-up fuses for frequent motor starting, within their breaking capacity. Fault level and starts per hour decide the choice.
An MV panel is a medium voltage switchgear panel, here for 3.3 kV to 11 kV. It is a metal-enclosed assembly with breakers, busbars and protection used for plant distribution and for controlling and protecting high voltage motors.
It is used for motor starting and for distribution from 3.3 kV to 11 kV, where large motors or feeders need switching and protection. It is common in plants with high voltage motors and in the incoming supply to transformers.
An MV panel works at levels such as 3.3 kV to 11 kV and uses breakers, clearances and protection suited to that voltage. An LT panel works at levels such as 415 V and is smaller in construction.
Send the system voltage, current rating, short circuit rating in kA, number of incomers, feeders and motor starters, protection relay needs, single line diagram and make preference. Price depends on rating, make and quantity, so send details for a quotation.
| Panel Type | MV switchgear |
|---|---|
| Standard | IEC 62271-200 |
| Voltage Class | 3.3 kV - 11 kV |
| Construction | Metal-enclosed, compartmentalised |
| Protection Degree | IP4X (typical) |
| Typical Use | HV motor and feeder control |
What a compact or packaged substation contains, how it differs from a conventional civil substation, when it makes sense and what to specify before you order.
6 min readTransformers & Power QualityA step-by-step method to size a 11 kV/415 V transformer for a factory or building, with a worked example, standard kVA ratings and the mistakes that…
6 min readSwitchgear, Panels & ProtectionFixed MCCs cost least, drawout MCCs cut downtime, and intelligent MCCs add data. Here is how to decide which construction your plant actually needs.
6 min read