Compact Substation Transformer
Packaged compact substations that combine the HT switchgear, transformer and LT panel in one factory-assembled enclosure.
On request- StandardIEC 62271-202, IS 1180
- Voltage Class11 / 22 / 33 kV to LT

Download specification sheet (PDF)
Oil-filled distribution transformers that step grid voltage down to the utilisation level for plants, campuses and utilities.
Made to order against your specification. Fill what you know; our engineers will confirm the rest.
Representative image. The actual product, make and appearance depend on the supplier and your specification.
Also searched as: oil filled distribution transformer, 11 kV distribution transformer, step down transformer, ONAN distribution transformer, DT transformer
Distribution transformers are usually bought on a standard specification, so small details decide long-term cost. Start with kVA, primary and secondary voltage, vector group (Dyn11 is common in India), tap range and the standard, such as IS 1180 for ratings it covers.
Typical mistakes are oversizing, which raises no-load loss and lowers efficiency at light load, and omitting a plan for the LV side, where a bus duct or cable arrangement must handle high current. Verify the earthing, fittings and tests required by your DISCOM. Standard ratings and approvals should be confirmed with the manufacturer.
Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.
D is a delta-connected primary, yn a star secondary with an accessible neutral, and 11 the clock position, meaning the LV leads the HV by 30 degrees. It is widely used in distribution because it handles unbalanced single-phase loads well. Always match the vector group for parallel operation.
Add up maximum demand, apply diversity, allow room for growth, and avoid running it far below capacity. Overloading shortens life, but heavy oversizing wastes energy. Use the transformer sizing calculator as a starting point and verify the load profile.
A distribution transformer is the last voltage step before the supply reaches the user. It steps the grid voltage, such as 11 kV or 22 kV, down to the utilisation voltage of about 433 V used by plants, campuses and consumers.
Power transformers work at higher voltages in substations and generating stations and usually run near full load. Distribution transformers work at the load end at lower voltage and are loaded variably through the day, so they are designed for good all-day efficiency.
Distribution transformers are commonly built to IS 1180, with IS 2026 as the general power transformer standard. The standard and efficiency level that apply to your order depend on your utility or project specification.
Send the kVA rating, primary and secondary voltage, vector group, cooling type, tap changer requirement, impedance, indoor or outdoor use and any loss level requirement. Quotations are prepared within 24 hours of receiving the details.
| Transformer Type | Oil immersed, distribution |
|---|---|
| Cooling | ONAN |
| Standard | IS 1180 / IS 2026 |
| Voltage Class | 11 kV or 22 kV / 433 V |
| Vector Group | Dyn11 (typical) |
| Tap Changing | Off-circuit tap switch |