Substation Equipment
Substation Equipment

Download specification sheet (PDF)

Switchgear PanelsSKU SKE-SWG-020

Substation Equipment

Auxiliary equipment for substations: isolators, CTs, PTs, LAs, earthing and control items.

On request

Choose your specification

Every field is optional - tell us what you know and we will confirm the rest in the quotation.

WhatsApp

Representative image. The actual product, make and appearance depend on the supplier and your specification.

Overview

Also searched as: electrical substation equipment, substation accessories, substation items, substation isolators CT PT LA, power substation material

Typical applications

  • New substations
  • Upgrades and expansions
  • Maintenance replacement

Key features

  • Items supplied to your single-line
  • Compatible with major makes
  • Test certificates on request

Selection notes

Substation equipment is chosen by the system voltage and the fault level of the point it connects to. Collect these two facts before asking for isolators, current and potential transformers, lightning arresters or earthing items, since nearly every rating follows from them.

  • Isolators: match voltage class, current rating and short-time withstand current; decide on manual or motorised operation and any earthing switch.
  • CTs and PTs: choose ratio, accuracy class and burden separately for metering and for protection.
  • Arresters: select for the system voltage and the earthing arrangement.
  • Environment: in polluted or coastal sites, ask about creepage distance on insulators.
  • Earthing: design to the fault current and the soil resistivity, with step and touch voltages checked.

Coordinate with your DISCOM about their specifications and inspection. See current transformers, potential transformers and MV panels for related items, and earthing materials for earthing materials. Substation work must follow permits and be done by qualified staff.

To quote, please share

  • Single-line diagram and incomer / feeder schedule
  • System voltage, fault level (kA) and busbar rating
  • Switching devices and make preference
  • Indoor / outdoor, IP degree and ambient
  • Metering, protection and communication requirements

Ratings, dimensions and certification are confirmed against your enquiry. Use Send an enquiry and our engineers will respond within 24 hours.

Frequently asked questions

What do I need to specify substation equipment?

System voltage, fault level, indoor or outdoor mounting, the single-line diagram and the quantities of each item. For CTs and PTs also give ratio, class and burden. Earthing design requires soil resistivity data as well.

Why does pollution matter for insulators?

Dirt and moisture on insulators create conductive paths that cause flashover. Coastal and industrial sites need longer creepage distances or other measures. Longer creepage distance, insulator washing or special coatings may be used in such areas, and the right choice depends on the severity of pollution.

Who approves a substation design?

Usually your DISCOM or the utility, together with the electrical inspectorate, apply their own requirements. Check what applies to your project early. The rules differ from state to state, so confirm early with the authority concerned to avoid redesign and delay in energisation.

What equipment is used in a substation?

Common items include isolators, circuit breakers, current transformers, potential transformers, lightning arresters, earthing systems and control and protection items. The exact list depends on the voltage level and the design of the substation.

What are CT and PT in a substation?

CT is a current transformer and PT is a potential transformer. They step down high current and voltage to safe levels for meters and protection relays, so that the power system can be measured and protected without connecting instruments directly to the line.

What are the types of substation equipment?

Equipment can be grouped as switching devices such as isolators and breakers, measuring devices such as CTs and PTs, protective devices such as lightning arresters and relays, and earthing and control items. Outdoor and indoor versions are used.

What details are needed for a substation equipment quotation?

Send the item list with ratings, system voltage, current rating, fault level, indoor or outdoor use, applicable standard and make preference. Price depends on model, rating, make and quantity, so send details for a quotation.

Technical specification

Panel TypeSubstation equipment
StandardIS / IEC as applicable
Voltage ClassLT to 33 kV
ConstructionOutdoor / indoor
Protection DegreeAs applicable
Typical UseSubstation construction